Official publication of Magadh University and Kolhan University, Government of Bihar and Jharkhand, India
Year : 2016
Volume : Volume 6
Issue : Issue 2
Address for correspondence :
Dr. Shantanu Mulay
drshantanu.mulay@gmail.com
Aim: The purpose of this study is to investigate the most accurate impression technique and to know the influence of the tray type and impression material in transferring the intraoral position of implant fixture to working cast. Materials and methods: An acrylic resin model of edentulous model, 12 implant analogs of standard imension , 3.3mm in diameter of Hitech brand are used. Two types of clear acrylic custom trays that are open window and closed window custom trays were fabricated. Two types of impression posts were used, namely closed window impression post and open window impression posts. Two types of impression materials are used those are polyether medium body ( impregum) and polyvinyl siloxane heavy and light body used. Type IV die stone is used. 30 impressions by using open window and 30 by closed window techniques were made. Casts were made. CMM machine is used to record the measurements in 3D. Results: Statistical analysis shows that there is significant difference between open window technique and closed window technique. But there is no significant difference found between two impression materials that are polyether and polyvinyl siloxane . Conclusion: Open window tray technique is much better than closed window tray technique for making implant impressions. Both impressions materials, polyether and polyvinyl siloxane are ideal impression materials for implants.
Keywords: Open window tray, Closed window tray, Coordinated measuring machine.